Mk-3000 series operation, Notice – MK Diamond MK-3000 Series User Manual

Page 21

Advertising
background image

21

2. Remove arbor bolt. If blade is mounted on right side saw, the bolt has left hand threads. To

remove turn clockwise. If the blade is mounted on left side of saw, nut has right hand threads.

To remove, turn counter-clockwise (Figure 8).
3. Remove outer flange (Figure 9).

4. Install new blade (Figure 10).
5. Install the outer flange on to the blade flange (Figure 11).

MK-3000

SERIES OPERATION

BLADE MOUNTING INSTRUCTIONS

1. Remove Blade Guard.

Fig. 6 Unscrew Hose Fitting

NOTICE

Before mounting the blade, machine should be turned “OFF”. Clean the blade collars and stub shaft.

Fig. 7 Hold Blade Guard

Fig. 8 Remove Arbor Bolt

Fig. 9 Remove Outer Flange

Fig. 10 Install New Blade

Fig. 11 Slide Outer Flange in place

A. Unscrew the hose fitting to disconnect hose (Figure 6).

B. Hold the Blade Guard by the handle (Figure 7). Release the inner latch.

C. Pull the Blade Guard up and off the Saw.

Advertising