Replacing the return line filter, Replacing the return line filter 61 – MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-30 User Manual

Page 61

Advertising
background image

Replacing the Return Line Filter

Model 505G2.20 - 505G2.30 SilentFlo™ HPU

Maintenance

61

Replacing the Return Line Filter

The filter element of the HPU should be replaced for the following reasons:

When the dirty-filter indicator lights

Whenever the hydraulic fluid is changed

The filter manufacturer’s recommended maximum interval has passed
(1000 hours or 6 months)

Prerequisite

You will need a filter element (MTS part number 010-053-349) or a filter kit
(MTS part number 100-078-099).

Procedure

To change the filter element:

Note

The dirty-filter indicator may light when the HPU is first started due to low
hydraulic fluid temperature. When the HPU is at normal operating
temperature, recheck the indicator to determine if the element actually
needs replacement.

1. Turn off the HPU.

2. Open the top of the HPU with a 8-mm (5/16-inch) allen wrench.

Return Line Filter Component Identification

3. Check the output pressure gage. Be sure the pressure is at zero before

proceeding.

Note

You can remove the filter from the top of the HPU if you are careful. If
you want easier access to the filter, you can remove the front panel. The
front panel is secured to the HPU with screws along each side and the
bottom of the panel.

Output
Pressure
Gage

Filter
Housing

Advertising