Inspecting the Heat Exchanger

Model 505G2.20 - 505G2.30 SilentFlo™ HPU

Maintenance

67

6. Remove the end bonnet from the water intake side of the heat exchanger.

If you have to remove a mounting bracket, use blocks of wood to support
the exchanger.

7. Internally inspect the exchanger for:

Corrosion and erosion damage to the tubes and tube ends

Fouling and corrosion deposits on the tubes

Condition of the optional zinc anodes

Damaged threads

8. If no further cleaning is needed, reassemble the heat exchanger using new

gaskets.

9. If there is evidence of fouling (sediments or light scale) or corrosion,

perform a mechanical or chemical cleaning as needed. Consult the Heat
Exchanger Care and Water Quality Guide
(part number 015-164-000) for
more information on mechanical and chemical cleaning.