Hpu setup, Hpu setup 31 – MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-30 User Manual

Page 31

Advertising
background image

HPU Setup

Model 505G2.20 - 505G2.30 SilentFlo™ HPU

Installation

31

6. Check for unusual noises or leaks. If a problem is found, press the Stop

button. You must correct the problem before you continue.

7. Turn the High/Low/Start switch to the High position.

8. Verify the correct output pressure, as shown on the pressure gage.

A. Adjust the pressure if necessary.

B. If the pressure is adjusted, the auto-cooling function may need to be

adjusted.

9. Press the Stop button to shut down the unit.

HPU Setup

The following procedure should only be performed at HPU installation to verify
settings, when you replace the user interface panel, or if you need to change a
selection.

1. Rotate the power disconnect switch to the on (|) position.

2. On the user interface Main Display, select the language.

3. On the user interface Main screen ensure that the Remote Operation button

is not selected (gray), indicating the HPU is in local mode.