Model 505G2.20 - 505G2.30 SilentFlo™ HPU

36

Precharging the Surge Suppressor Accumulator

Installation

Checking the

precharge pressure

The nitrogen precharge should be about 50–60% of the output pressure. Monitor
the pressure gage. If the pressure reading is outside the range of 10.3–12.5 MPa
(1500–1800 psi), perform the procedure “Changing the precharge pressure.”

Charging Kit

Changing the

precharge pressure

The nitrogen precharge should be within the range of 10.3–12.5 MPa (1500–
1800 psi) which is 50–60% of the output pressure (21 MPa or 3000 psi). Perform
one of the following procedures to change the precharge pressure:

Decreasing pressure

To decrease the precharge pressure:

1. Slowly open the bleed valve on the charging kit until gas begins to escape.

When the pressure reading on the appropriate pressure gage drops to the
level required, close the bleed valve.

2. Close the locknut. Open the bleed valve on the accumulator charging kit and

remove the chuck valve from the accumulator.

3. Install the valve stem cap and protective cover.

Increasing pressure

To increase the precharge pressure:

1. Close the locknut on the accumulator.

2. Open the bleed valve two turns.

High Pressure Gage
0–21 MPa (0–3000 psi)

Gage Protector
(factory set to limit
pressure to the
gage to

Extension

Bleed

Input

Nitrogen Supply

Regulator

Nitrogen

Core-Type Valve
To Open and Close

Nitroge

Nitrogen
Bottle

Regulator
Output

Regulator
Shut-Off

You must supply these

Check

Locknu

Valve

Ope

Clos

Poppet-Type Valve
To Open and Close

Close

Valve

Valve

Open

Open

Clos

Low Pressure Gage
0–2.1 MPa (0–300

Advertising
This manual is related to the following products: