MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-30 User Manual

Page 44

Advertising
background image

Model 505G2.20 - 505G2.30 SilentFlo™ HPU

44

Status Screen

Operation

Oil Temp OK/Oil Temp Fault

Indicator. Used to indicate if the hydraulic fluid temperature is
within acceptable limits.

Oil Temp OK - gray: Indicates the hydraulic fluid temperature is
within acceptable limits.

Oil Temp Fault - red: Indicates the hydraulic fluid temperature is
not within acceptable limits and an interlock is active.

Motor OK/Motor Overload

Indicator. Used to indicate if the pump motor is in an acceptable

operating condition.

Motor OK - gray: Indicates the pump motor is within an

acceptable operating condition.

Motor Overload- red: Indicates the pump motor has overheated

and an interlock is active.

Motor Sequence OK/Motor Sequence
Fault

Indicator. Used to indicate if the pump motor sequence is

operating properly.

Motor Sequence OK - gray: Indicates the motor sequence is not in

a fault condition and operating properly.

Motor Sequence Fault- red: Indicates that the PLC commanded

the motor contactor to close but the contactor did not close after a

10 second time period.

Return Filter OK/Return Filter Fault

Indicator. Used to indicate if the return filter is within acceptable

limits.

Return Filter OK - gray: Indicates the contamination in the return

filter is within acceptable limits.

Return Filter Dirty - yellow: Indicates the contamination in the

return filter is not within acceptable limits. This state will not

generate an active interlock, but alerts the user that the filter
requires maintenance.

The HPU cannot be started with an active return filter warning

Pressure Filter OK/Pressure Filter
Fault

Part of the Pressure Filter Option; only
displayed if the Pressure filter Option
was purchased.

Indicator. Used to indicate if the pressure filter is within

acceptable limits.

Press Filter OK - gray: Indicates the contamination in the pressure

filter is within acceptable limits.

Press Filter Dirt y- yellow: Indicates the contamination in the

pressure filter is not within acceptable limits. This state will not
generate an active interlock, but alerts the user that the filter

requires maintenance.

The HPU cannot be started with an active pressure filter warning.

Screen select buttons

These pushbutton/indicators are described in the Main Screen

section; refer to

“Main Screen”

on page 40.

Name and Location

Description

Advertising