Model 505G2.20 - 505G2.30 SilentFlo™ HPU

32

HPU Setup

Installation

4. On the user interface panel, press and hold the Setup button for five seconds

to display the Setup HMI (human-machine interface) screen.

5. The following table describes the pushbuttons and indicators on the Setup

screen.

Name and Location

Description

Use Buttons Below To Change
Parameters

Indicator - blue-green: Provides instruction for the setup screen.

Remote Fault Normal/Remote Fault
Reverse

Pushbutton /Indicator. The HPU generates fault signals for remote

monitoring. This button is used to define the polarity of the output
signal.

Remote Fault Normal - gray: The remote fault signal is active high
meaning the fault contact is closed when a fault is present.

Remote Fault Normal - black: The remote fault signal is active
low meaning the fault contact is open when a fault is present.