Model 505G2.20 - 505G2.30 SilentFlo™ HPU

64

Replacing the Hydraulic Fluid

Maintenance

6. If there still is any uncertainty regarding fluid quality, obtain another sample

of the fluid and have it analyzed. The fluid tests should include chemical
analysis, particle count, and viscosity checks. Most oil companies have
facilities for performing these tests, or consult MTS Systems Corporation.

7. Close the needle valve and remove the hose and valve assembly. Open the

needle valve.

Replacing the Hydraulic Fluid

Replace the hydraulic fluid in the HPU reservoir whenever you have determined
that the hydraulic fluid is no longer suitable for use.

Appearance of Hydraulic Fluid Sample

Fluid Properties

Problem

What to Do

Dark colored fluid

Indicates chemical breakdown or

the hydraulic fluid has been allowed
to rise above the maximum

recommended temperature (severe

overheating)

Analyze the fluid and replace as

required by the analysis.

If the cause was overheating, flush the

entire system to remove varnish or
residue. Consult your MTS Field

Service Engineer to determine if

changes or adjustments to your
hydraulic system are required.

Burnt odor

Indicates chemical breakdown or

the hydraulic fluid has been allowed
to rise above the maximum

recommended temperature (severe

overheating)

Analyze the fluid and replace as

required by the analysis.

If the cause was overheating, flush the

entire system to remove varnish or
residue. Consult your MTS Field

Service Engineer to determine if

changes or adjustments to your
hydraulic system are required.

Opaque fluid

Indicates chemical breakdown

Replace the fluid

Milky appearance

Indicates water is present in the
fluid

Check the heat exchanger for damage.

Look for other water sources if the

water does not appear to be coming
from the heat exchanger.

Identify and correct the source of the

water leakage and replace the fluid if

necessary.

Sediment at the bottom of
the sample container (after
sample has stood
overnight)

Indicates collapsed, ruptured, or

clogged filter(s)

Analyze the fluid and replace all filter

elements.

Clean the fluid or replace it as required

by the analysis.