Maintenance :


- The fuel system is self-venting.

Note :

Collect any emerging fuel and dispose of in an environmentally responsible

manner using a fuel filter !

______________________________________________________________________________________

8.8 Battery:

Danger


- When working with the battery, no

open flame, no smoking !

Do not allow acid to come into contact
with clothes or skin !

Wear protective goggles

Do not lay any tools on the battery !



The batteries “B” are located on the left and right sides of the oil tank (fig. 31). It is very important to keep
clean the battery and to carry out maintenance correctly in order to have a perfect function of this battery. If
the machine is out of action for a longer period of time the battery has to be pinched off in order to prevent a
deep discharge. Especially the terminals and clamps must be cleaned regularly and afterwards be greased
thickly with an acidproof grease.

Note :

Dispose

of

old

batteries

correctly.

_____________________________________________________________________________________

8.9 Tightening the screws :


Fillister-head screw M 16 x 25 DIN 912-8.8

Fillister-head screw M 16 x 40 DIN 912-

8.8ightening torque 300 NM / 221 ft-lb

Tightening torque 220 Nm / 165 ft-lb













Hexagonal screw M 16 x 40 DIN 933-8.8

Tightening

torque

220

Nm

/

165

ft-lb

Fig. 31

Fig. 33

Fig. 32