3.4.3

Management Processor VLAN Support

The 2FXM Management Processor can independently transmit and receive Management Data with an
IEEE 802.1Q tag. To enable and configure this feature, type 9 from the Management Options screen to
access the Other Networking Features screen.

PI

SA

Management Options

iConverter, Serial Agent

Network Management

1: Chassis and Module Management

2: Set Module Identifier

Management Module Preferences

3: IP and Control Preferences

4: SNMP Preferences

5: Abandon Preference Changes

6: Save Preference Changes

7: Restore to Factory Defaults

8: Restart Management Module

9: Other Networking Features

Management Module Maintenance

10: Firmware Update

11: Set Date/Time

IP Address = 192.168.1.220

Chassis Number = 1

Enter Choice, (H)elp, E(x)it > 9

PI

SA

Other Networking Features Screen

iConverter, Serial Agent

1: Enable/Disable DHCP Client

Disabled

2: Enable/Disable Keep Alive Trap

Disabled

3: Keep Alive Trap interval (10-600 secs)

10

4: Enable/Disable SW1 Switch Block

Enabled

5: Serial Baud Rate

57600 bps

6: Enable/Disable VLAN Support

Disabled

7: VLAN ID (0-4095)

2

8: VLAN Priority (0-7)

7

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To configure the VLAN management ID, select option 7. To configure the priority setting for the VLAN
management channel, select option 8. To enable or disable VLAN management support, select option 6.
Once VLAN support is enabled, IP management support will only be accessible using the configured
VLAN ID.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.