2 module management mode, Module management mode – Omnitron Systems Technology iConverter 2FXM User Manual User Manual

Page 27

Advertising
background image

4.2

MODULE MANAGEMENT MODE

From the Module configuration screen, the management mode can be changed. Select option 18 to change
the mode. The management mode options will be displayed.

PI

Module - iConverter 2FXM iConverter, Serial Agent

Identifier -

Chassis Number

= 1

Switch ON condition

OFF condition

H/W

Actual

Slot Number

= 11

1: Pause Enabled

Pause Disabled Off

Off

Model Number

= 8959-0

2: Port 1 HDX

Port 1 FDX

Off

Off

3: Not Available

Serial Number

= xxxxxxxx

4: Not Available

Manufacturing Date = xxxxxxxx

5: Port 2 HDX

Port 2 FDX

Off

Off

Product Revision

= xx

6: Link Propagate

Link Segment

Off

Off

Software Revision

= xx

7: Remote Fault

Normal

Off

Off

8: Symm Fault Det

Normal

Off

Off

LED

9: BP A Enabled

BP A Disabled

Off

Off

1: Power

= On

10: BP B Enabled

BP B Disabled

Off

Off

2: Power Supply 1 = Off

11: Not Available

3: Power Supply 2 = Off

12: Slave Only

Master/Slave

Off

Off

4: Power Supply 3 = Off

13: Not Available

5: Port 1 Link = Off

14: Not Available

6: Port 1 FDX = Off

15: Not Available

7: BP Master = Off

16: Not Available

8: Port 2 Link = Off

OAM settings:

9: Port 2 FDX = Off

17: IP protocol State On

18: Management Mode Secure OAM

Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >

Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3

The 2FXM module supports several management options. Option 18 configures how the module will
communicate to its remote partner. ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses
Omnitron’s proprietary secure encrypted management channel. ‘Auto Secure OAM’ will force the remote
partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to
communicate with the remote partner over the secure protocol. The management channel can support IP or
IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17. ‘Auto ah OAM’
(option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification. ‘Auto ah OAM’ will
force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to
communicate with the remote partner over the ah protocol. This option provides an industry standard
method of fault detection and monitoring. The management channel supports both IP and IP-less connectivity
based on the configuration, option 17 and 18.

NOTE: See NetOutlook User Manual for complete information on the management modes.

Page 27

Advertising