2 board-mounted bank 2 settings, Install module and connect cables, When multiple management modules such as the – Omnitron Systems Technology iConverter 2FXM User Manual User Manual

Page 8

Advertising
background image

3.2.2

Board-Mounted Bank 2 Settings

PI

DIP-switch Bank 2 is only available on the plug-in module.

Switch

Left (Factory Default)

Right

SW1

A-DS:
Backplane Port A Disabled

A-EN:
Port A Enabled

SW2

B-DS:
Backplane Port B Disabled

B-EN:
Port B Enabled

SW3

Reserved

Reserved

SW4

M/SL:
Master/Slave Auto-Select

SL:
Slave-Mode Only

SW5 - SW8 Reserved

Reserved

3.2.2.1

SW1 - Backplane Port A Enabled “A-DS/A-EN”

When the DIP-switch is in the Left “A-DS” position (factory default), Backplane Port A of the 2FXM is
isolated from the chassis Backplane. When the DIP-switch is in the Right “A-EN” position, Backplane
Port A of the 2FXM is enabled. This port allows Ethernet Backplane connectivity to an adjacent module
via the chassis Backplane Port A. See the backplane illustrations in Section 2.1.3.

3.2.2.2

SW2 - Backplane Port B Enabled “B-DS/B-EN”

When the DIP-switch is in the Left “B-DS” position (factory default), Backplane Port B is isolated from the
chassis Backplane. When the DIP-switch is in the Right “B-EN” position, Backplane Port B is enabled.
This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port B.
See the backplane illustrations in Section 2.1.3.

3.2.2.3

SW4 - Master/Slave Auto-Select and Slave-Only “M/SL / SL

When multiple management modules such as the

iConverter

NMM and the 2FXM (or multiple self-managed

modules such as 2FXM) are installed in the same chassis, only one management module can act as the
chassis master. The master management module has the ability to make changes to the settings of the other
modules in the chassis, while the slave management modules cannot make the changes. If an NMM is
installed in the chassis, the NMM will always be the master, otherwise the lowest slot number with a
management module installed will become chassis master.

When this DIP-switch is in the Left “M/SL” position (factory default), the assignment of mastership is
automatically negotiated by the installed management modules. To designate a specific management module
as the master when no NMM is installed in the chassis, set the DIP-switch on the master module to the Left
“M/SL” position, and set the other installed management modules’ DIP-switches to the Right “SL” position
to enable Slave-Only mode.

Only the chassis master can change configuration settings of other modules.

3.2.2.4

SW3, SW5, SW6, SW7, SW8 - Reserved

These DIP-switches are for factory use only.

NOTE: DIP-switches marked Reserved must be kept in the Left (factory default) position.