Iconverter, Module power chassis user manual – Omnitron Systems Technology iConverter 5-Module Chassis User Manual

Page 3

Advertising
background image

Page 3

iConverter

5-Module Power Chassis

User Manual

1. 0 GENERAL DESCRIPTION

The

iConverter

1U (1.75 inch) 5-Module Power Chassis is powered by up to two (2) hot-swappable and redundant universal AC

or DC power supplies and can accommodate up to 5

iConverter

modules. It is ideal for enterprise Local Area Network (LAN) or

Metropolitan Area Network (MAN) applications where managed media converters with high density and small rack-footprint are

important.

Figure 1:

iConverter

5-Module Chassis (Shown without modules installed)

This User Manual describes the following models:

Configuration

5-Module Chassis

AC

(33 watts)

AC

High Airflow

(66 watts)

24VDC

(33 watts)

48VDC

(33 watts)

48VDC

High Airflow

(66 watts)

One (1) Power Supply

8220-1

-

8226-1

8225-1

-

Two (2) Power Supplies

8220-2

8221-2

8226-2

8225-2

8227-2

Spare Power Supply

8220-9

8221-9

8226-9

8225-9

8227-9

23” Rack Mount Kit

8092-2

Blank Module Panel

8090-0

For wide temperature (-40 to 60° C) add a “W” to the end of the model number. Consult factory for

extended temperature (-40 to 75° C) models.

1.1

Mechanical Description

The

iConverter

5-Module chassis consists of two AC or DC power supplies. As can be seen from the model table above, the

5-Module chassis models have been pre-configured with two power supplies. The power supplies provide power to the chassis’

5 backplane connectors.

1.2

Backplane Architecture

The chassis features 5 module slots numbered 1 (left-most positioned slot) through 5 (right-most positioned slot).
Backplane A and Backplane B provide Ethernet connectivity between adjacent slots.

Figure 2:

iConverter

5-Module Chassis Backplane Architecture

Figure 2 depicts the backplane architecture of the chassis showing Backplane A and Backplane B connectivity.
Backplane A connects odd numbered slots on the left to even numbered slots on the right (i.e. 1-2, 3-4).
Backplane B connects even numbered slots on the left to odd numbered slots on the right (i.e. 2-3, 4-5).
When modules with Backplane capabilities are inserted into adjacent chassis slots, they can connect to each other via the Ethernet

backplanes when enabled, creating a flexible network architectures.
This chassis architecture facilitates a variety of applications including unmanaged, in-band managed and multi-port configurations.

Advertising