Dip-switch bank 1, 2) install module in chassis and connect cables – Omnitron Systems Technology iConverter T1/E1 Plugin Module User Manual

Page 2

Advertising
background image

DIP-SWITCH BANK 1

BOARD MOUNTED DIP-SWITCH SETTINGS:

T1/E1 Copper Line Configuration Settings:

The T1/E1 copper line codes and line lengths are configured using board mounted
DIP-switches.

Line Type

Port Type

Distance

DIP-Switch Position

1

2

3

4

T1 DSX-1

(default)

RJ-45/48

0' to 133'

Down

Down

Down

Down

T1 DSX-1

RJ-45/48

133' to 266'

Down

Down

Down

Up

T1 DSX-1

RJ-45/48

266' to 399'

Down

Down

Up

Down

T1 DSX-1

RJ-45/48

399' to 533'

Down

Down

Up

Up

T1 DSX-1

RJ-45/48

533' to 655'

Down

Up

Down

Down

T1 DS1

RJ-45/48

0 dB

Down

Down

Down

Down

T1 DS1

RJ-45/48

-7.5 dB

Down

Up

Down

Up

T1 DS1

RJ-45/48

-15 dB

Down

Up

Up

Down

T1 DS1

RJ-45/48

-22.5 dB

Down

Up

Up

Up

E1 75 ohm

Coax/BNC

Standard

Up

Down

Down

Down

E1 120 ohm

RJ-45/48

Standard

Up

Down

Down

Up

E1 75 ohm

Coax/BNC

Extended

Up

Down

Up

Down

E1 120 ohm

RJ-45/48

Extended

Up

Down

Up

Up

2) INSTALL MODULE IN CHASSIS AND CONNECT CABLES

a. Carefully slide the module into an open slot in the chassis. Align the module with

the installation guides and ensure that the module is firmly seated against the
backplane. Secure the module by fastening the front panel thumbscrew (push in
and turn clockwise to tighten) to the chassis front. Verify the “Pwr” LED is ON
(indicating the chassis is powered).

b. When using the SFP model (8719-0 or 8739-0), insert the SFP Fiber transceiver

into the Port 1 SFP receptacle on the T1/E1 converter (see the SFP Data Sheet
091-17000-001 for supported transceivers).

NOTE: The release latch of the SFP Fiber transceiver must be in the closed
(up) position before insertion.

c. Connect to the RJ-45/48 connector on the

iConverter

T1/E1 converter via a Category 3

or better cable (Category 5 is recommended), and attach the other end to the network
equipment.

d. Connect an appropriate multimode or single-mode fiber cable to the fiber port of

the installed module. It is important to ensure that the transmit (TX) is attached to
the receive side of the device at the other end and the receive (RX) is attached to
the transmit side. Single-fiber (SF) media converter models operate in pairs. The
TX wavelength must match the RX wavelength at the other end and the RX
wavelength must match the TX wavelength at the other end.

operation and returns a signal to the local unit (see Figure C). A slow blinking “Tst”
LED on the local unit and a fast blinking “Tst” LED on the remote unit shows confirmation
that the fiber segment is communicating properly between devices. By returning the
DIP-switch to the “Norm” position, the unit resumes normal operation.

Figure B: Dual Loopback Mode

Figure C: Fiber Optic Test Mode

SW3 - FORCE 1S TO FIBER “FO1”

When this DIP-switch is set to the “FO1” position, an “all ones” pattern is inserted
into the data stream being transmitted out of the fiber port on the
T1/E1 converter. Data being received on the coax or twisted pair is disabled and
data being received on the fiber is passed through to the coax or twisted pair side. By
returning the DIP-switch to the “Norm” position, the unit resumes normal operation.

SW4 - FORCE 1S TO COAX OR UTP “CU1”

When this DIP-switch is set to the “Cu1” position, an “all ones” pattern is inserted into
the data stream being transmitted out of the coax or twisted pair port on the
T1/E1 converter. Data being received on the fiber will be disabled and data being
received on the coax or twisted pair is passed through to the fiber side. By returning
the DIP-switch to the “Norm” position, the unit resumes normal operation.

SW1 AND SW2 - AMI/B8ZS/HDB3 MODE

B8ZS (T1) or HDB3 (E1) is the default line encoding mode of operation. To select AMI
mode, enable both the Local Dual Loop-back “Loop” and Fiber Optic Test “FOT”
DIP-switches on the front of the module.

PUSH BUTTON - MANUAL CROSSOVER “= / X”

The Manual Crossover “= / X” button located on the front panel is used to eliminate the
need for crossover and custom cables when connecting devices to the RJ-45/48 port.
When the button is in the out “=” position, the port is configured for a straight-through
cable. When the button is in the in “X” position, the port is configured for a crossover
cable. The twisted pair connection requires two active pairs in a T1/E1 environment.
The active pairs are pins 1 & 2 and pins 4 & 5. Only dedicated wire pairs should be
used for the active pins.