Note: It is not permitted to set both media converters to any RFD mode. A lockup condition

will occur.

Figure 2: Link Modes

For detailed information on the operation of the different Link Modes, download the application
note

“iConverter

Link Modes” available on Omnitron’s web page:

http://www.omnitron-systems.com/downloads_iconverter.php

2) INSTALL STANDALONE MODULE AND CONNECT CABLES
a. The STM-1 converter is available in tabletop and wall-mount models. For wall-mounting,

attach the STM-1 converter to a wall, backboard or other flat surface. For tabletop

installations, place the unit on a flat level surface. Attach the rubber feet to the bottom

of the STM-1 converter to prevent the unit from sliding. Make sure the unit is placed in

a safe, dry and secure location.

To power the unit using the AC/DC adapter, connect the AC/DC adapter to an AC outlet.

Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm

DC barrel connector (center-positive) on the unit. Confirm that the unit has powered up

properly by checking the power status LED located on the front of the unit.

To power the unit using a DC power source, prepare a power cable using a two conductor

insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the

length required. Strip approximately 3/8 of an inch of insulation from the power cable

wires. Connect the power cables to the unit by fastening the stripped ends to the DC

power connector.

Connect the power wires to the DC power source. The Power LED should indicate the

presence of power.

WARNING: Note the wire colors used in making the positive and negative connections.

Use the same color assignment for the connection at the DC power source.

NOTE: If mounting with a safety ground attachment, use the safety ground screw at the

rear of the unit.

b. Insert the 155Mbps OC-3 SFP into Port 1 SFP receptacle on the STM-1 converter.

NOTE: The release latch of the fiber transceiver must be in the closed position before

insertion.

c. The STM-1e interface on the converter utilizes mini BNC connectors. When connecting

to full size BNC connectors use the supplied adapter cables.

Page 2

Page 3

d. Connect an appropriate multimode or single-mode fiber cable to the fiber transceiver

port on the STM-1 converter. It is important to ensure that the transmit (Tx) is attached

to the receive side of the device at the other end and the receive (Rx) is attached to the

transmit side.

WARNING: Do not attempt to remove the STM-1e device from the module. This will cause

damage to the module and the STM-1e device.

3) VERIFY OPERATION
Once the module has been installed and configured per steps 1 and 2, verify the module is

operational by viewing the LED indicators.

Legend

Color

OFF State

ON State

Pwr

Amber

No power applied

Unit is powered

P1 Lk

Green

Port is not linked

Port is linked

P2 Lk

Green

Port is not linked

Port is linked

Table 3: LED Indicators