Ordering information, Specifications management, Iconverter – Omnitron Systems Technology iConverter 10/100 User Manual

Page 2: Netoutlook

Advertising
background image

Ordering inFOrmatiOn

Page 2

800-675-8410 • 949-250-6510 • www.omnitron-systems.com • [email protected] • 140 Technology Dr., Irvine, CA 92618

iConverter

10/100

© 2012 Omnitron Systems Technology, Inc. All rights reserved.

iConverter

and

NetOutlook

are Registered Trademarks of Omnitron Systems Technology, Inc.

Trademarks are owned by their respective companies. Specifications are subject to change without notice.

091-18380-007M

2/12

speciFicatiOns

management

Management is accomplished by using a Network Management

Module (NMM2) or a media converter with integrated management

(such as an

iConverter

10/100M2) that provides monitoring,

remote configuration and trap notification. The management

module can be accessed via SNMP, Telnet and via a serial

port. The SNMP-based management is accomplished via

Omnitron’s intuitive, graphic-oriented

NetOutlook

management

software or third party SNMP management software, while the

Telnet and the serial interfaces have an easy-to-use, menu-

driven interface.
Some of the real-time 10/100 parameters that can be monitored

include power, link and data receive status. Other parameters

include module type and model, hardware and software

revisions, serial numbers, and an user-defined identifier.
The user can override the 10/100 module’s physical

DIP-switch settings using SNMP or Telnet to remotely configure

DIP-switch-selectable parameters such as auto-negotiation,

Half/Full-Duplex, Link Mode selection, and Ethernet Backplane

selection.
In addition to all standard

iConverter

SNMP traps such as

module insertion and removal, the 10/100 modules can

generate traps on port state changes including link-up and

link-down. Trap monitoring of specific events can be selectively

enabled or disabled by the network administrator.

Model Type

10/100

Protocols

100BASE-FX, 10BASE-T,

or 100BASE-TX

UTP Connectors

RJ-45

Fiber Connectors

SC, ST, LC, Single-Fiber SC

Controls

UTP X-over, LS/LP, RFD, Auto/Man,

10/100, FDX/HDX

LED Displays

Power, FO link, UTP link, Auto,

UTP FDX/HDX, F/O FDX/HDX, 10, 100

Dimensions

W:0.85" x D:4.5" x H:2.8"

Weight

8 oz.

Compliance

UL, CE, FCC Class A, NEBS Level 3

Power Requirement

0.95A @ 3.3VDC (typical)

Temperature

Standard: 0 to 50º C

Wide: -40 to 60º C

Storage: -40 to 80º C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

1,050,000

Model Type

Fiber /

Media

Type

Distances

Connector Types

Tx

Wavelength

(nm)

Rx

Wavelength

(nm)

Min. Tx

Power

(dBm)

Max. Tx

Power

(dBm)

Min. Rx

Sensitivity

(dBm)

Max. Rx

Sensitivity

(dBm)

Link

Budget

(dBm)

ST

SC

LC

10/100

Dual Fiber

MM

2km

8380-6

8382-6

-

850

850

-10

-4

-24

-3

14

MM

5km

8380-0

8382-0

8386-0

1310

1310

-24

-14

-31

-14

7

SM

30km

8381-1

8383-1

8387-1

1310

1310

-15

-8

-31

-8

16

SM

60km

8381-2

8383-2

8387-2

1310

1310

-5

0

-31

-3*

26

SM

120km

-

8383-3

8387-3

1550

1550

-5

0

-31

-3*

26

10/100

Single-Fiber

SM

20km

-

8390-1

-

1310

1550

-15

-5

-30

-3

15

SM

40km

-

8390-2

-

1310

1550

-8

0

-30

-3*

22

SM

60km

-

8390-3

-

1310

1550

-5

0

-31

-3*

26

SM

20km

-

8391-1

-

1550

1310

-15

-5

-30

-3

15

SM

40km

-

8391-2

-

1550

1310

-8

0

-30

-3*

22

SM

60km

-

8391-3

-

1550

1310

-5

0

-31

-3*

26

For wide temperature (-40 to 60º

C), add a "W" to the end of the model number. Consult factory for extended temperature (-40 to +75º

C) models and other fiber

configurations. When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.

*A minimum of 3dB of attenuation is required for these models.

Advertising