Application, Specifications, Telecom application: mobile backhaul – Omnitron Systems Technology iConverter 4xT1/E1 MUX/M User Manual

Page 2

Advertising
background image

APPLICATION

Telecom Application: Mobile Backhaul

The following application shows an example of the iConverter

4xT1/E1 MUX/M used in a hybrid TDM/Ethernet transport

network.

A wireless service provider has enhanced their network to

support 3G/4G services. The new equipment uses Ethernet

for backhaul at the Cell Site, while the existing legacy 2G/2.5G

equipment uses TDM (T1) for backhaul.

Using the iConverter 4xT1/E1 MUX/M at the Cell Site, the

service provider is able to multiplex up to four T1/E1 circuits and

one 10/100/1000 Ethernet on a fiber transport link. The fiber

carries the multiplexed traffic to a second iConverter 4xT1/E1

MUX/M that is installed at the Base Station Controller (BSC)

and Radio Network Controller (RNC). The 4xT1/E1 MUX/M

converts the legacy TDM traffic back to T1/E1 interfaces,

where they are connected to the TDM network. The MUX also

converts the Ethernet traffic back to a 10/100/1000 interface,

where it is connected to the provider’s IP network.

Page 2

SPECIFICATIONS

iConverter

4xT1/E1 MUX/M

Description

iConverter

4xT1/E1 MUX

Managed T1/E1 Multiplexer

Date Rates

T1 or ISDN PRI:

E1:

Ethernet:

1.544Mbps
2.048Mbps
10/100/1000Mbps

(900Mbps throughput)

Standard

Compliances

ANSI: T1.403, T1.102
AT&T: T62411
ITU: G.703, G.704, G.706, G.736, G.755, G.823, G.824, G.8261
ETSI: ETS 300 166
IEEE 802.3

Regulatory

Compliances

UL, CE, FCC Class A, RoHS2, WEEE

Frame Size

Ethernet:

Up to 10,236 bytes

Port Types

Copper:

Fiber:

T1/E1 (RJ-45/RJ-48)
10/100BASE-T (RJ-45)
Proprietary (ST, SC, Single-fiber SC, SFP)

Cable Types

Copper:

Fiber:

Category 3 or better for T1/E1

(T1: 100 Ohm, E1: 120 Ohm)

(Active Pairs are Pins 1, 2 and 4, 5)
EIA/TIA 568A/B, Cat 5 UTP and higher for

Ethernet
Multimode: 50/125µm, 62.5/125µm
Single-mode: 9/125µm

AC Power

Requirements

AC Input:

100 to 240VAC 50/60Hz

0.5A @ 120VAC
IEC320 Connector

DC Power

Requirements

DC Input:

18 to 60VDC; 2.0A

@ - 48VDC

3-Pin Terminal

Dimensions

W: 6.7” x D: 5.51” x H: 1.87”
L: 435.6 mm x B: 228.6 mm x H: 44.5 mm

Weight

2.5 lb (1.14 kg)

Temperature

Commercial:

Wide:

Storage:

0 to 50°C
-40 to 60°C
-50 to 80°C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

AC Model:

DC Model:

137,000
148,000

Warranty

Lifetime warranty with 24/7/365 free Technical Support

Advertising