Application, Specifications, Telecom application: mobile backhaul – Omnitron Systems Technology iConverter 4xT1/E1 MUX/M User Manual
Page 2

APPLICATION
Telecom Application: Mobile Backhaul
The following application shows an example of the iConverter
4xT1/E1 MUX/M used in a hybrid TDM/Ethernet transport
network.
A wireless service provider has enhanced their network to
support 3G/4G services. The new equipment uses Ethernet
for backhaul at the Cell Site, while the existing legacy 2G/2.5G
equipment uses TDM (T1) for backhaul.
Using the iConverter 4xT1/E1 MUX/M at the Cell Site, the
service provider is able to multiplex up to four T1/E1 circuits and
one 10/100/1000 Ethernet on a fiber transport link. The fiber
carries the multiplexed traffic to a second iConverter 4xT1/E1
MUX/M that is installed at the Base Station Controller (BSC)
and Radio Network Controller (RNC). The 4xT1/E1 MUX/M
converts the legacy TDM traffic back to T1/E1 interfaces,
where they are connected to the TDM network. The MUX also
converts the Ethernet traffic back to a 10/100/1000 interface,
where it is connected to the provider’s IP network.
Page 2
SPECIFICATIONS
iConverter
4xT1/E1 MUX/M
Description
iConverter
4xT1/E1 MUX
Managed T1/E1 Multiplexer
Date Rates
T1 or ISDN PRI:
E1:
Ethernet:
1.544Mbps
2.048Mbps
10/100/1000Mbps
(900Mbps throughput)
Standard
Compliances
ANSI: T1.403, T1.102
AT&T: T62411
ITU: G.703, G.704, G.706, G.736, G.755, G.823, G.824, G.8261
ETSI: ETS 300 166
IEEE 802.3
Regulatory
Compliances
UL, CE, FCC Class A, RoHS2, WEEE
Frame Size
Ethernet:
Up to 10,236 bytes
Port Types
Copper:
Fiber:
T1/E1 (RJ-45/RJ-48)
10/100BASE-T (RJ-45)
Proprietary (ST, SC, Single-fiber SC, SFP)
Cable Types
Copper:
Fiber:
Category 3 or better for T1/E1
(T1: 100 Ohm, E1: 120 Ohm)
(Active Pairs are Pins 1, 2 and 4, 5)
EIA/TIA 568A/B, Cat 5 UTP and higher for
Ethernet
Multimode: 50/125µm, 62.5/125µm
Single-mode: 9/125µm
AC Power
Requirements
AC Input:
100 to 240VAC 50/60Hz
0.5A @ 120VAC
IEC320 Connector
DC Power
Requirements
DC Input:
18 to 60VDC; 2.0A
@ - 48VDC
3-Pin Terminal
Dimensions
W: 6.7” x D: 5.51” x H: 1.87”
L: 435.6 mm x B: 228.6 mm x H: 44.5 mm
Weight
2.5 lb (1.14 kg)
Temperature
Commercial:
Wide:
Storage:
0 to 50°C
-40 to 60°C
-50 to 80°C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
AC Model:
DC Model:
137,000
148,000
Warranty
Lifetime warranty with 24/7/365 free Technical Support