Omnimux, User’s manual – Omnitron Systems Technology OmniMux 400 User Manual

Page 3

Advertising
background image

Omnitron Systems Technology, Inc.

3

GENERAL DESCRIPTION

The OmniMux 400 is an IBM 5250 and 5250 Express compatible Multiplexer/
Demultiplexer device that replaces up to 8 AS/400 or System 34/36/38 TWINAX
controller cables with a multiplexed link. The following models are discussed in this manual:

STANDARD

EXPRESS

DESCRIPTION

(MM/SM)*

(MM/SM)*

2700/2720

2740/2760

8 Ports, RJ11/45 to F/O and RJ11/45

2701/2721

2741/2761

8 Ports, TWX to F/O and TWX

2702/2722

2742/2762

4 Ports, RJ11/45 to F/O and TWX

2703/2723

2743/2763

4 Ports, TWX to F/O and TWX

2704/2724

2744/2764

2 Ports, RJ11/45 to F/O and RJ11/45

2705/2725

2745/2765

2 Ports, TWX to F/O and TWX

2710/2730

2746/2766

8 Ports, RJ11/45 and DB25 to F/O and RJ11/45

2711/2731

2747/2767

8 Ports, TWX and DB25 to F/O and TWX

2750/2770

2748/2768

8 Ports, DB25 to F/O and TWX

The OmniMux 400 operates in pairs; the Multiplexer is connected to the host, and
the Demultiplexer is connected to the distant twinax devices, either directly in a
daisy-chained fashion or via a Mux hub device.
The OmniMux diagnostic features make it easy to install and maintain. It detects
and displays true port activity, line quality, and true data parity errors. This is
accomplished by individual port monitoring and searching for legal sync and frame
header patterns. Upon the detection of a valid frame pattern, a per-port green LED
indicator displays the detected activity. This feature assists in installation and in the
selection of correct polarity baluns. The active port data is analyzed for correct
parity and the detection of parity error is indicated by a per-port red LED. This
feature facilitates the continuous monitoring of signal and line quality.
Host and device ports support polarity configuration which facilitates the usage of
different balun types.
The OmniMux utilizes a Digital Phase Locking architecture. Combined with its
repeating, regenerating and reshaping features, the OmniMux delivers an
unmatched level of performance and reliability. Exploiting the Data Frame
Regeneration and Sync Bits Reconstruction facilitates cascading the OmniMux via
OmniStar 400’s for complex site configurations. This powerful feature is very useful
in scattered terminal environments.

OmniMux

TM

400

Systems AS400/3X

5250 and 5250 Express

Multiplexer/Demultiplexer

User’s Manual

*MM=Multimode, SM=Single-mode

10

Omnitron Systems Technology, Inc.

n Cable Types:

Fiber Optic:

50/125, 62.5/125, 100/140 micron

UTP:

Level 3 (EIA/TIA 568): 24 AWG solid copper

100 +/- 15 ohms @ 1.0 MHz 7.8 db per 1,000 ft.

@ 1.0 Mhz (Lower grade wiring supported at

shorter distances)

n Data Rate:

Standard 5250:

1 Mbps -2%, +4%

5250 Express:

1 or 2 Mbps -2%, +4%

n Supported Distances:

Host/Device to Mux:

Twinax:

5,000 ft.

UTP:

3,000 ft.

DB25:

50 ft.

Mux to Mux:

Twinax:

5,000 ft.

UTP:

3,000 ft.

Multimode fiber:

15,000 ft.

Single-mode fiber:

30,000 ft.

n Indicators:

Power:

Yellow LED (1)

Activity:

Green LED (10)

Parity Error:

Red LED (10)

n Physical Dimensions:

Rackmount:

W:19.0”xD:6.0”xH:1.75”

Tabletop:

W:17.5”xD:6.0”xH:1.75”

n Weight:

2 .5 lbs.

n Power:

115 or 230 VAC, 100/50 mA

n Temperature:

Operating:

0° to 40°C

Storage:

-40° to 75°C

Humidity:

Up to 90% (non-condensing)

TECHNICAL SUPPORT

For assistance in installing this product, contact Omnitron’s Technical Support Department.

Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address:

Omnitron Systems Technology, Inc.

27 Mauchly #201

Irvine, CA 92618, USA

Email:

[email protected]

URL:

www.omnitron-systems.com

Advertising