Description:

The FlexCeiver family of transceivers are compatible
with IEEE 802.3 and Ethernet Versions 1.0 / 2.0. They
enhance networking media connectivity using 10Base-FL
with single-mode (SM) and multimode (MM) fiber,
10Base-2 thin coax and 10Base-T twisted pair (UTP).

All FlexCeivers have a 15-pin AUI connector that
attaches to a mating AUI connector mounted on hosting
Ethernet DTE equipment such as a workstation or a
PC, or on a repeater such as a hub or a switch.

This FlexCeiver 10T model is described here:

Model Maximum Distance

4210

100 meters / 328 ft.

The 4210 model provides a switch selectable full-duplex
operation that allows data to flow between two Ethernet
switches or a PC and a switch in both directions
simultaneously, doubling the 10 Mbps half-duplex
Ethernet to 20 Mbps.

Wire polarity errors are automatically corrected by the
FlexCeiver and the correction is indicated by an LED.

Mounting:

Insert the Omnitron FlexCeiver 10FL into the 15-pin
AUI port on a PC, workstation, hub or switch; slide the
connector latch locking it into place. If an AUI cable is
used, it is limited to 50 meters (164 ft.). Attach a RJ45
equipped UTP category 3 or higher (4 or 5) cable to the
10T’s RJ45 connector. Note that the total length of the
cable should not exceed 100 meters (328 ft.). The far
end of the cable must connect to repeater equipment
such as a hub or a switch. Connecting to another DTE
type (PC) is possible via a crossover cable.

Switch Settings:

“SQE” switch: When attaching to a PC (or a workstation),
the SQE switch should be set to “SQE Enable” (factory
setting). When connecting to a hub or a switch, it
should be set to “SQE Disable.”

“Duplex” switch: When attaching to a hub or a PC
connected to a hub, the Duplex switch should be set to
“Half Duplex” (factory setting). When attaching to an
Ethernet switch or a PC (or workstation) attached to an
Ethernet switch, the FlexCeiver can be set to “Full
Duplex.” To take advantage of the 20 Mbps full duplex
performance, the PC Network Interface Card (NIC)
must also be set to “Full Duplex.”

LED indicators:

LED

Color Description

Transmit

Green

Transmitted data activity

Receive

Green

Received data activity

Link Active

Green

Operational device at the far
end

Jabber Err

Red

Attached host unit violated
transmission time, could indicate
a faulty Network Interface Card
(when attached to a PC).

Polarity Invert Yellow Correction activated for

reversed UTP wires

SQE Enable

Yellow “SQE Enable” indicator

Full Duplex

Yellow “Full Duplex” indicator

Collision

Yellow Collision (normal operation)

Technical Support:

If you encounter problems in installing or maintaining
this product, contact Omnitron Technical Support:

Phone:

(949) 250-6510

Fax:

(949) 250-6514

Email:

[email protected]

Address:

Omnitron Systems Technology, Inc.
27 Mauchly #201
Irvine, CA 92618 USA

User Warranty Registration

Please complete both sides and mail or fax this registration form to:

Omnitron Systems T

echnology

, Inc.

27 Mauchly #201

Irvine, CA 92618 USA

Fax: (949) 250-6514

Name:

_________________________________________________

Company:

______________________________________________

Address:

______________________________________________

______________________________________________

City: ___________________ State:

_______ Zip

Code:

________

Country:

_______________________________________________

Phone: ____________________ Fax:

_______________________

E-mail:

_________________________________________________

Please complete both sides of this form

Notes:

____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
_____________________________
____________________________
____________________________
____________________________
____________________________
____________________________
____________________________

User Warranty Registration

Please complete both sides and mail or fax this form to the address indicated on

the other side.

FlexCeiver T

ype:

S

10FL

S

1

0

T

S

10B2

S

Other ___________

Model:

__________________________________________________

Serial Number: ______________ Purchase Date:

________________

Purchased From: ____________________________________________

Address:

________________________________________________

City: ___________________ State: _______ Zip Code:

__________

Country:

__________________________________________________

Comments and

Suggestions:

_________________________________

__________________________________________________________

Warning

The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other
than that contained in the operating instructions,
unless you are qualified and certified to do so by
Omnitron Systems Technology, Inc.

Caution

All user-required operations can be performed without
opening the unit. Never attempt to open or remove the
cover or tamper with the unit.

Warranty

This product is warranted to the original purchaser against
defects in material and workmanship for a
period of TWO YEARS from the date of shipment. A
LIFETIME warranty may be obtained by the original
purchaser by REGISTERING this product with
Omnitron within 90 days from the date of shipment. TO
REGISTER, COMPLETE AND MAIL OR FAX THE
REGISTRATION PORTION OF THIS INSTRUCTION
MANUAL TO THE INDICATED ADDRESS. During the
warranty period, Omnitron will, at its option, repair or
replace a product which is proven to be defective.

For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense.
Omnitron will pay the shipping charge to return the
product to Buyer’s designated US address using
Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects
resulting from improper or inadequate use and/or
maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing,
unauthorized modifications or tampering with equipment
(including removal of equipment cover by personnel
not specifically authorized and certified by Omnitron),
or misuse, or operating outside the environmental
specification of the product (including but not limited to
voltage, ambient temperature, radiation, unusual dust,
etc.), or improper site preparation or maintenance.

No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for
any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.

Form:040-04210-001-B 10/03

Advertising