GENERAL DESCRIPTION

The FlexCenter 10 is a 12/24 port 10Base-T flexible workgroup Ethernet hub repeater. It
features two optional interface modules capable of uplink interface to multimode and
single-mode fiber or coax devices or hubs.

This User’s Manual describes the following models:

Model

Description

4100

12 Port 10Base-T hub, rack-mountable.

4101

12 Port 10Base-T hub, stackable.

4102

24 Port 10Base-T hub, rack-mountable.

4103

24 Port 10Base-T hub, stackable.

The following modules are supported by the FlexCenter 10:

Model

Description

4110

10Base-FL Fiber uplink module, multimode, 850nm.

4111

10Base-FL Fiber uplink module, single-mode, 1300nm.

4112

10Base-FL Fiber uplink module, multimode, 1300nm.

4120

10Base-2 Coax uplink module.

The FlexCeiver’s 12/24 RJ45 ports provide 10Base-T interface to category 3 or higher
unshielded twisted pair (UTP) wiring. Its fiber interface modules provide 10Base-FL
multimode and single-mode ST connectivity options for a variety of applications. Its
coax interface module provides BNC 10Base-2 interface capability.

Being a smart repeater, the FlexCenter monitors and reports port activity. It detects
operational devices connected and displays their connection via a per port green
“Activity” LED. When sensing received data, the “Activity” LED starts blinking. If a
port violates transmission rules, it is disconnected automatically (partitioned) and a
red “Partition” LED displays the error status. The port is reconnected only after
normal behavior is restored; at that time the LED is turned off.

The hub detects and corrects polarity reversals in UTP wiring. It also detects and
displays collisions using a yellow “Collision” LED. Jabber conditions are displayed
using a red “Jabber” LED.

The FlexCenter features a special uplink RJ45 connector. This uplink connector is
equipped with a cross-over switch that can switch between the receiving and
transmitting wire pairs. This feature eliminates the need for a “Crossed Cable”
which is otherwise required when connecting between hubs.

10

Omnitron Systems Technology, Inc.

Application 6. Multiple fiber backbone

This case depicts three 10Base-T hubs interconnected using two fiber segments.
The collision rule is met (4-3-0) while restricting each fiber segment to 500 m. A
detailed calculation reveals (not provided here) that a total budget of 3,250 m of fiber
is available which would allow for instance for one of the fibers to be at 2 km while the
other could be 1,250 m.

Application 7. Switched fiber backbone

This application depicts a switched fiber backbone with the FlexCenter hubs and the
FlexPoint 10FL/T converters providing the fiber connectivity. Each "branch" segment
radiating from the switch is a separate "collision domain" and the collision rules apply
to each one independent of any other. Each one of the branching LANs meets the
collision rule (3-2-0).

Advertising