7 • Description

Eagle Instruction Manual

probe has a male quick connect fitting. Normally, the male end of
sample hose is installed in the Eagle inlet fitting and the probe is
installed in the female end of the hose. However, if the sample hose is
not needed for monitoring a particular area, the probe may be
installed directly to the inlet fitting. Sample hose lengths are available
from 5 feet (standard length) to 125 feet (see “Appendix A: Parts List”
on page 53).

CAUTION:

Sample hose lengths of more than 125 feet are not recommended
for the Eagle because of flow rate reduction and increased
response time. Consult RKI Instruments, Inc. for hose lengths
longer than 125 feet.

A super toxic probe is included with instruments that require it. It has
a plastic fitting and is connected to the inlet of the Eagle with a tubing
stub. See “Appendix C: Non-Standard Toxic Gas Sensors” on page 57
for more information about the super toxic probe and where to use it.

The standard probe includes a replaceable particle filter and
hydrophobic filter disk that prevent particulates and water from
entering the Eagle’s flow system. See “Replacing the Probe’s Particle
Filter and Hydrophobic Filter Disk” on page 48 for instructions to
replace the particle filter and hydrophobic filter disk.

Standard

Probe

Sample Hose