Eagle Instruction Manual

Alarms • 16

STEL Alarm (Toxics Only)

If a toxic gas channel’s average gas reading for the past 15 minutes
exceeds the STEL alarm setting:

STEL

displays in the alarm field for that channel.

• The channel’s display line flashes.

• The buzzer sounds a pulsed tone.

• The alarm lights flash.

TWA Alarm (Toxics Only)

If a toxic gas channel’s average gas reading for the past 8 hours
exceeds the TWA alarm setting:

TWA

displays in the alarm field for that channel.

• The channel’s display line flashes.

• The buzzer sounds a pulsed tone.

• The alarm lights flash.

Over Range Alarm

If a channel’s gas reading exceeds that channel’s full-scale setting:

OVER

displays in the alarm field for that channel.

• The channel’s display line flashes.

• The buzzer sounds a pulsed tone.

• The alarm lights flash.