Chapter 4: operation, Overview, Normal operation – RKI Instruments Beacon 200 User Manual

Page 27

Advertising
background image

Overview • 27

Chapter 4: Operation

Overview

This chapter describes the Beacon 200 Gas Monitor in normal operation.
This chapter also describes the Beacon 200 in alarm 1, alarm 2, and fail
conditions and suggests response to these conditions.

Normal Operation

Normal operation is defined as follows:

The start-up procedure is complete.

The Beacon 200 is not indicating an alarm 1, alarm 2, or fail condition.

The Beacon 200 is not running the Channel Control & Setup or
Calibration Programs.

During normal operation, the Beacon 200 simultaneously displays the
current gas reading, unit of measure, and target gas for each active
channel.

The PILOT light is on during normal operation indicating that the Beacon
200 is receiving incoming power.