Alarm Indications • 29

Alarm Indications

This section describes the Beacon 200 in alarm 1, alarm 2, and fail
conditions and suggests response to these conditions. Table 6 below lists
the alarm indications for each condition.

NOTE: The Beacon 200 includes alarm on and alarm off delay settings for

each channel and level of gas alarm. The alarm indications
described in this section operate according to the factory set delay
settings. See the Configure Channel Settings Menu section of
Chapter 5 for all the factory settings.

NOTE: You can select normally energized (NE) or normally de-energized

(NDE) channel relay settings in the Channel Control & Setup
menu. The following sections describe the default setting for the
channel relays which is NDE.

Common alarm 1 and alarm 2 relays are factory-set as NDE, and
the common fail relay is factory set as NE. The common relays’
NE/NDE settings are not user-adjustable.

Table 6: Visual and Audible Alarm Indications

Condition

Cause

Visual Indication(s)

Audible

Indication

Alarm 1

1

Increasing (decreasing for O

2

) gas

reading at or above the alarm 1 setpoint

ALARM 1 light is on

Gas reading flashes and
alternates with ALARM-1
message

Pulsing tone

Alarm 2

1

Increasing gas reading at or above the
alarm 2 setpoint

ALARM 2 light is on

Gas reading flashes and
alternates with ALARM-2
message

Pulsing tone

Fail

Disconnected or misconnected detector
wiring

Display reading below -10% of full scale or
lower

Defective components

FAIL light is on

FAIL message flashes in place
of gas reading

Steady tone

Low Battery

2

No AC power and DC power source
(primary or backup) less than 21.5 volts.

FAIL light is on

SUPPLY VOLTAGE IS TOO
LOW
LOW POWER
STANDBY
message and actual
voltage of incoming DC power

None

*

1

If the Beacon 200 is in both an alarm 1 and an alarm 2 condition, both alarm lights are on and the display

alternates between the gas reading and the ALARM-1 ALARM-2 message.

*

2

If DC power is used as primary or backup power source.