This appendix lists the part numbers and descriptions for replacement parts
and accessories offered for the Beacon 200 Gas Monitor.

Buzzer not
Working

The buzzer does not
sound an audible
alarm during alarm
conditions.

The buzzer sounds
weak or broken.

The buzzer is
disconnected or
misconnected.

The buzzer is
malfunctioning.

1.

Verify that the wiring to the BUZ- and
BUZ+ terminals of the controller terminal
strip is correct and secure.

2.

If the buzzer difficulties continue, contact
RKI for further instruction.

Reset Switch
not Working

The buzzer does not
silence when you
press the reset switch.

The applicable alarm
circuit does not reset
when you press the
reset switch after an
alarm condition
passes.

The reset switch is
disconnected or
misconnected.

The reset switch is
malfunctioning.

1.

Verify that the wiring to the RESET (2)
terminals of the controller terminal strip is
correct and secure.

2.

If the reset switch difficulties continue,
contact RKI for further instruction.

Table 12: Parts List, Beacon 200 Gas Monitor

Part No.

Description

18-0107RK

Conduit Hub (3/4 in.)

43-0440RK

Reset Switch

43-4165RK

AC Fuse, 1/4” x 1 1/4”, fast acting, 3A, 250 V

43-4170RK

DC Fuse, 1/4” x 1 1/4”, fast acting, 6A

52-1016RK

Buzzer

71-0059RK

Beacon 200 Gas Monitor Operator’s Manual (this document)

Table 11: Troubleshooting the Beacon 200 (Continued)

Condition

Symptom(s)

Probable Causes

Recommended Action