Chapter 5: channel control and setup program, Overview – RKI Instruments Beacon 200 Rig Monitor, LEL/LEL User Manual

Page 32

Advertising
background image

27 • Beacon 200 Rig Monitor Operator’s Manual

Chapter 5: Channel Control and Setup Program

Overview

The Channel Control & Setup Program allows viewing of and changes to
instrument setup parameters. It is accessed using the program buttons.
The Channel Control & Setup Program includes three menus as described
in Table 6.

To enter the Channel Control & Setup Program, simultaneously press and
hold the ESCAPE and ENTER buttons for approximately 5 seconds.

The Channel Control & Setup Program menu includes a 5-minute time-out
feature. If you do not press a button for 5 minutes, the Rig Monitor
automatically returns to normal operation.

NOTE: If the Beacon 200 Rig Monitor returns to normal operation

because of a program time-out, the active channels enter a warm-
up period just as they do when the unit is first turned on.

If you are installing a new system, the channels have been setup
at the factory for the ordered detector heads. Use the Channel
Control & Setup Program only if you want to disable or enable a
channel, delete a channel, or change channel settings. If a
channel is being added or a channel is being changed from one
type to another, contact RKI Instruments, Inc. for additional
documentation required to define the channel type.

Table 6: Channel Control & Setup Program Menus

Menu

Function

Enable/Disable Channel(s)

Configures channels as enabled, disabled, or not used

Configure Channel Settings

Configures alarm settings, noise filter setting, and zero
suppression setting for each channel

View System Information

Displays the firmware version number and the instrument
operating voltage