M2A Transmitter Operator’s Manual

6

Catalytic LEL Detectors

The catalytic LEL detectors have a 1/2” NPT thread and require a 3/4”NPT x 1/2”NPT reducer to
install in the detector hub. The rest of the detectors have a 3/4” NPT mounting thread and are
installed directly in the detector hub.

IR Detectors

The IR combustible detectors are generally used instead of the catalytic combustible detectors in
applications where there may be catalyst poisons such as silicone present or where oxygen is not
present in the monitoring environment.

Oxygen Detectors

There are four types of oxygen detectors available, a non-explosion proof partial pressure type, a
non-explosion proof capillary type, a non-explosion proof capillary type with a replaceable sensor,
and an explosion proof (CSA) capillary type with a replaceable sensor. The capillary type’s output
is less susceptible to variations in atmospheric pressure than the partial pressure type. The CSA
type oxygen detector (65-2514RK) and one of the non-explosion proof capillary type detectors
(65-2494RK) have a replaceable plug-in sensor inside the detector housing while the entire oxygen
detector must be removed if replacement is required for the other two.

Figure 2: 65-2514RK Oxygen Detector, CSA

Cl

2

, 0 - 3 ppm

65-2300RK-CL2

Cl

2

, 0 - 10 ppm

65-2300RK-CL-10

PH

3

, 0 - 1 ppm

65-2300RK-PH3

SO

2

, 0 - 6 ppm

65-2300RK-SO2

Table 2: M2A Detectors

Target Gas, Range

Detector(s) Used

Flame Arrestor
Guard

Detector Housing Cap

Oxygen Sensor

Detector Housing Body

Cap Gasket