Remote sense operating mode using prm, Local sensing (single ended), Switch – Vicor VI Chip Remote Sense PRM Evaluation Board User Manual

Page 21: Position on or off connection number, Table 7. switch configuration in local sensing

Advertising
background image

UG:016

vicorpower.com

Applications Engineering: 800 927.9474

Page 21

Remote Sense Operating Mode using PRM

®

: Local Sensing (Single Ended)

Mode select switch S10 setting: keep the switch S10 setting at all positions as shown in
following illustration.

The following table describes the switch configuration.

In this configuration, PRM operates in Remote Sense. PRM module output voltage is
sensed through divider formed by R29 and R31. U11B is configured as buffer as shown
in Figure 11 and provides the sense voltage to error amplifier U11A. R33, R41 and R27
are left open, reserved for differential sensing and current sensing. R29 is set to limit
the upper trim range based on a maximum reference voltage of 1.25 V. Note that by
default compensation components are not installed and required for operation. Default
compensation components are provided with the board as described in a later section.

LOCAL SENSE (Single Ended)

ON

OFF

1

2

3

4

5

6

7

8

9

10

Postion

number

Switch

Position

ON or OFF

Connection

Number

1 OFF

TM pin must be left open. This switch position cannot be put in the

ON position.

2

ON

PR pin is connected to output of external error amplifier.

3 ON

IF pin is connected to output of external current sense amplifier to set

constant current limit.

4 ON

RE pin is connected to input of the external voltage reference circuit

to generate voltage reference for external error amplifier.

5

ON

VS pin is connected to power VCC of the op-amp and current sense IC.

6

OFF

NC pin must be left open. This switch position cannot be put in the ON position.

7 ON

PRM +OUT pin is connected to local sense (single ended) of the remote

sense control circuitry.

8

Don’t care

9

OFF

See next Remote Sense Operation

10

OFF

See next Remote Sense Operation

Table 7.

Switch configuration

in local sensing

SG

SG

VCC

R32

1206

C22

1206

EAO

R33

1206

SG

R41

1206

+SENSE_B

-SENSE_B

LOCAL SENSE_+

2

3

1

4

8

SO8

U11A

6

5

7

U11B

1206

54.9K

R29

1206

1.27K

R31

1206

1.27K

R42

1206

1K

R36

C21

0603

IMON

R27

1206

H 48

H 47

H 51

H 52

1206

20Ω

R30

H 46

H 45

TP38

TP37

OPEN

OPEN

OPEN

OPEN

OPEN

VREF

To PR through S10

Preinstalled component

and connections

User installed

component

C19

1206

1206

20K

R28

1206

4.7nF

C20

H 39

H 40

H 43

H 44

H 42

H 41

To PRM +OUT

through S10

AC signal

injection

Figure 12.

Remote Sense: local sensing

(single ended) control circuitry

BLUE highlight =

Pre-installed component

GREEN highlight =

user installed component

Figure 11.

Local Sensing

(single ended)

Advertising