Test Points Description

Each test point has a socket which accepts 0.015 – 0.025 inch diameter leads for easy
installation of solid wires and through-hole components. All the test points are brought
out to the edge of the board to allow for easy measurement and/or connection to the
user’s external circuitry. All test points are labeled and routed to the edge of the board.
Each test point is accompanied with an adjacent socket for adding a test lead or to
facilitate wiring to external circuitry.

Reference

Functional

Functional

Designator

Name

Description

TP30, +IN,

Input voltage test points provide kelvin connection to input pins of the PRM

®

.

TP33 -IN

Use these test points for measuring the input voltage of the PRM to avoid

error due to interconnect losses.

TP31, +OUT,

Output voltage test points provide kelvin connection to output pins of the PRM.

TP32 -OUT

Use these test points for measuring the output voltage of the PRM to avoid

error due to interconnect losses.

TP34,

TP21,

SG

Signal Ground (SG) test points are the ground reference for all control circuitry

TP22

and signal pins of the PRM.

TP28,

CS+,

TP29

CS-

Used to measure the output current of the PRM across shunt resistor R25.

TP35,

IM,

TP36

SG

Used to measure the output of current sense IC with reference to SG.

TP10 PR

Used to measure the PR signal of the PRM with reference to SG test point.

TP11

NC

No Connect. For internal use only.

TP12

TM

Used to measure the TM signal of the PRM with reference to SG test point.

TP13

VS

Used to measure the VS signal of the PRM with reference to SG test point.

RE

TP14

Used to measure the RE signal of the PRM with reference to SG.

TP15

NC

No Connect. For internal use only.

TP16

PC

Used to measure the PC signal with reference to SG.

TP17

VC

Used to measure the VC signal with reference to SG.

TP18 IF

Used to measure the IF signal of the PRM with external constant current circuit

with reference to SG in Remote Sense Operation.

TP43,

VREF

Used to measure the voltage reference signal of the error amplifier with reference

TP44

to SG in Remote Sense Operation.

TP19,

TP20

NC

No connect. For internal use only.

TP37,

Can be used to inject the isolated signal of network analyzer for bode plot

TP38

measurement to measure the stability in Remote Sense Operation.

TP23,

VG,

Can be used to connect function generator to control the open drain

TP24

SG

MOSFET in ENABLE control.

TP39,

Not Applied.

TP41

TP40,

Not Applied.

TP42

Table 3.

Test points description

Note: for RS PRM, silkscreen

may not match pin name.

See section: Considerations for

Remote Sense only PRM