Vicor VI Chip Remote Sense PRM Evaluation Board User Manual

Page 3

Advertising
background image

UG:016

vicorpower.com

Applications Engineering: 800 927.9474

Page 3

Considerations for Remote Sense only PRM

This board is designed to accomodate different types of PRMs. Therefore, certain
circuitry on the board is not populated and there are additional considerations for using
Remote Sense only PRMs.
The Remote Sense PRM Evaluation Board does not operate in default switch S10 setting
which has all switches in the OFF position. Switch at position 1 must remain in the OFF
position. Putting switch at position 1 in the ON position could short the TM pin which
would cause damage. Switch at position 6 must remain in the OFF position as well.
Please see appropriate section for switch setting and mode of operation.
The silkscreen may not match the pin names for Remote Sense PRM. Following table
maps pin names of the Remote Sense PRM to silkscreen and standard PRM.

Remote Sense PRM

PRM

Silkscreen on the Board

PR

SHARE/CONTROL NODE

SH/CN

PC

ENABLE

EN

TM

TRIM

TRIM

NC

NC

TP20

NC

NC

TP19

NC

AL

AL

VC

VC

VC

RE

REF/REF_EN

RE

SG

SGND

SG

IF

IFB

IFB

VS

VAUX

VAUX

NC

VT

VT

Contents

All Remote Sense PRM evaluation boards arrive with the following contents.
(The user guide can be downloaded from the www.vicorpower.com)

n

1 x Remote Sense PRM evaluation board

n

1 x VI Chip push pin heat sink

n

2 x VI Chip push pins for heat sink installation

n

2 x VI Chip push pin heat sink grounding clips

n

1 x hardware kit

n

1 x through-hole aluminum-electrolytic input capacitor (C

IN

)

n

1 x through hole resistor for default compensation (R28)

n

1 x through hole capacitor for default compensation (C20)

n

2 x jumpers

Table 2.