Remote sense, Operating mode: prm & vtm, Current limit adjustment in remote sense operation – Vicor VI Chip Remote Sense PRM Evaluation Board User Manual

Page 24: Slave operating mode (arrays)

Advertising
background image

UG:016

vicorpower.com

Applications Engineering: 800 927.9474

Page 24

The slew rate of the output voltage during startup may be controlled by controlling
the rate-of-rise of the voltage at VREF node. This can be achieved using soft-start
capacitance C24. By default, C24 is populated with 0.1 uF ceramic capacitance.
Sockets H55 and H56 can be used for installation of additional through-hole soft-start
capacitance. It is not recommended to extend the soft start beyond 10msec.

Current Limit Adjustment in Remote Sense Operation

In Remote Sense Operation, current feedback is provided externally. The current limit
set point is a function of the current sense amplifier gain, the shunt resistor and the
internal current limit threshold of PRM. Full chip PRM evaluation board has 5 mΩ
current shunt whereas half chip PRM evaluation board has 10mΩ current shunt. The IFB
current limit threshold is fixed at 2.0 V. The gain of the current sense amplifier can be
changed per Equation 2 in order to adjust the current limit. Resistor R26 set the gain of
the current sense amplifier. R25 is the current shunt.

By default, R26 is installed for the current limit approximately 10% above rated
output current.
The current limit setpoint can be changed by adjusting the value of R26 and
appropriately setting the gain of the current sense IC.

Slave Operating Mode (Arrays)

Mode select switch S10 setting: keep the switch S10 setting at all positions as shown in
the following illustration.

Slave operation is required for constructing arrays of parallel devices as described in the
next section. Switch all the positions to OFF, except position #3.

Slave PRMs receive their

control signal (PR) from an external remote sense circuit. Switch at position #3 is on
to enable the constant output current limit. External Remote Sense circuit controls the
array of voltage.

G

CS

=

V

IFB_IL

I

LIMIT (SET) •

R

25

Equation 2

REF_EN_B

C23

0603

VREF

TP44

TP43

SGND

1206

R45

1206

R43

1206

C24

GN

D

3

IN

1

OUT

2

U12

SOT23_3

H 55

H 56

R44

VOLTAGE REFERENCE

Figure 15.

Voltage reference circuit

SLAVE

ON

OFF

1

2

3

4

5

6

7

8

9

10

Postion

number

Figure 16.

Slave

Advertising