Weidmuller PT 100/4 signal conditioners for current output User Manual
Page 15

33
7
Notes on CE labelling of WAVESERIES modules
WAVESERIES modules, that carry CE-labelling, fulfil the requirements
of the EU-Guidelines 89/336/EU “electromagnetic compatibility” and
the therein listed harmonised European Norms (EN).
The declarations of conformity are, in accordance with the above-
mentioned EU-Guideline, Article 10, held at the following address
for the r elevant authorities:
Weidmüller Interface GmbH & Co.
Postfach 3030
32720 Detmold
8
Technical data
Input
Sensor types
PT 100/4 Select C accor ding to DIN
IEC 751
Input curr ent
1.35 mA ... 1.45 mA ... 1.60 mA
Connection type
selection using DIP switches
Conductor r esistance
≤
50
Ω
(3- and 4-wir e connection)
Influence of conductor
resistance
max. ± 0.005 °C/
Ω
for 3- and 4-wir e
connection
Input range
-200 ... +800 °C adjustable using
DIP switches
Offset
input range up to +25 % possible