Step 5: Remove the
Existing SCR Modules

1. Remove the bus bars in order to access the SCR Modules in the drive:

If removing the SCR Modules from a Regenerative drive, refer to

Remove the Bus Bars from a Regenerative Drive

below.

If removing the SCR Modules from a Non-Regenerative drive, refer

to

Remove the Bus Bars from a Non-Regenerative Drive on page -14

.

Remove the Bus Bars from a Regenerative Drive

2. Remove the two screws or bolts and washers that secure the (red and

blue) wires from the AC Line Snubber board to the terminal bus bars (C
and D) and remove the wires.

3. Remove the three bolts and washers that secure the (black) wires from

the resistors to the terminal bus bars (U, V and W) and remove the
wires.

=

Regenerative Drive

Remove bolts, washers and wires

Remove screws, washers and wires