What you need to do, Step 1: remove power from the drive – Rockwell Automation 20P PowerFlex DC Drive - Frame B SCR Modules User Manual

Page 2

Advertising
background image

2

PowerFlex® DC Drive - Frame B SCR Modules

What You Need to Do

To install the SCR Modules:

❐ Step 1: Remove power from the drive
❐ Step 2: Remove the power wiring
❐ Step 3: Remove the protective covers
❐ Step 4: Remove the Pulse Transformer and Switching Power Supply

boards

❐ Step 5: Remove the existing SCR Modules
❐ Step 6: Install the new SCR Modules
❐ Step 7: Install the Pulse Transformer board and Switching Power

Supply board

❐ Step 8: Replace the protective covers, power wiring and document

the change

Step 1: Remove Power
from the Drive

1. Remove and lock-out all incoming power to the drive.

ATTENTION: Remove power before making or breaking cable
connections. When you remove or insert a cable connector with
power applied, an electrical arc may occur. An electrical arc can
cause personal injury or property damage by:

sending an erroneous signal to your system’s field devices,
causing unintended machine motion

causing an explosion in a hazardous environment

Electrical arcing causes excessive wear to contacts on both the
module and its mating connector. Worn contacts may create
electrical resistance.

L1

L2

L3

O

I