GuardShield™ Type 2 Safety Light Curtain Installation Instructions

9

Original instructions

Figure 5: Determining machine stopping time and safety distance

Multiple GuardShield Type 2

When two or more GuardShield Type 2 are mounted in close proximity
to one another, it may be possible for the receiver of one GuardShield
Type 2 pair to receive infrared light from the transmitter of another
GuardShield Type 2 pair. If two or more pair of GuardShield Type 2 are
mounted in the same plane, the transmitter and receiver pairs must be
mounted in accordance with Figure 6 or a barrier is used to guard against
optical interference.

Figure 6: Multiple GuardShield Type 2 alignment options

Mounting Brackets

The GuardShield Type 2 is mounted using right angle brackets attached
to the endcaps of both transmitter and receiver. It may be necessary to use
additional brackets to mount the GuardShield Type 2 at a proper safety
distance from the machinery hazard.

Figure 7: Mounting brackets

Optional Middle Mounting Bracket (440L-AF6108)

Figure 8:

Note: Middle mounting brackets should be used in vibration

applications for protective heights of 1120 mm and larger.

Middle of Depth of Protective Field

Safety Distance

Point of Operation

Top of tool

Bottom of tool

To avoid the possibility of
standing between the protective
field and the point of operation,
the distance must be maintained.

Protective Field Marking

Machine stop time

Transmitters emit in opposite
direction. Each receiver receives only
the beams of the appropriate
transmitter.

Positioning of the light curtain:
Transmitters emit in opposite
direction.

42

(1.65)

20

(0.79)

40 (1.57)

18.9

14.5

52 (2.04)

3.0

32

(1.25)

6.5 (0.26)

49.2 (1.93)

40.2

62

24

30 (1.18)

20 (0.78)