GuardShield™ Type 2 Safety Light Curtain Installation Instructions

10

R

Original instructions

Electrical Installation

Connections

Power Supply

The external voltage supply (+24V DC) must meet the requirements of
IEC 61496-1. In addition, the following requirements have to be
fulfilled:

• A short-term power failure of 20 ms must be bridged by the power

supply.

• The power supply has double insulation between the primary and

the secondary side.

• The power supply is protected against overload.
• The power supply corresponds to the guidelines of the EWG

(industrial environment).

• The power supply corresponds to the Low Voltage Directives.
• The grounded conductor of the power supply device must be

connected to a grounded conductor PE.

• The maximum deviation of the voltage levels is 24V DC +/- 20%.

EDM Connection

Figure 9: Connecting the contact elements to the EDM

Start/Restart interlock

Note: Start/restart interlock requires a N.O. momentary push button or
key switch.

Figure 10: Connecting the reset button/restart button

Connections [mm (in.)]

Cables/Connectors

The GuardShield Type 2 transmitter connector is a four-pin DC micro
connector offered in cable lengths from 2 to 30 meters. The GuardShield
Type 2 receiver connector is an 8-pin DC micro connector offered in
cable lengths of 2 to 30 meters.

Standard GuardShield Type 2 Receiver Connector

Double insulation

This part of the insulation provides

supplementary insulation against

hazardous voltage levels.

Motor, etc.

Hazardous voltage level

Basic insulation

Hazardous

Hazardous

Reinforced

insulation or

double

Unit 1

Power

Supply Unit

Output (pink

Basic insulation

Basic insulation

0V (blue)

+24V (brown)

K1

K1

K2

K2

GuardS

hield

24V

Pin 4

5

6

K1

K2

k2

k1

Contactor

Contacts

Contactor

Coils

Transmitter Connection

Face View of

Female DC Micro

Color

Pin No.

Signal

Transmitter

Brown

1

+24V DC

White

2

No Connection

Blue

3

0V DC

Black

4

Machine Test Signal

Receiver Connection

Face View of

Female DC Micro

Color

Pin No.

Signal

Receiver

White

1

Auxiliary Output

Brown

2

+24V DC

Green

3

Ground

Yellow

4

EDM

Grey

5

OSSD 1

Pink

6

OSSD 2

Blue

7

0V DC

Red

8

Start/Restart

Pin 8

Reset/restart button

24V

1

4

3

2

2

1

5

8

7

6

4

3

Advertising