Original instructions – Rockwell Automation 440L GuardShield Type 2 Safety Light Curtain User Manual User Manual

Page 19

Advertising
background image

GuardShield™ Type 2 Safety Light Curtain Installation Instructions

17

R

Original instructions

GuardShield Type 2 Catalog Numbers

Catalog Number Explanation

Sensor Pair

Transmitter

Receiver

Resolution—mm (in)

No. of Beams

Protective

Heights—

mm (in)

Pair Weight— kg

(lbs)

440L-P2K

⊗0160YD

440L-T2KA0160YD

440L-R2K

⊗01604D

30 (1.18)

8

160 (6.2)

0.9 (1.9)

440L-P2K

⊗0320YD

440L-T2KA0320YD

440L-R2K

⊗0320YD

30 (1.18)

16

320 (12.59)

1.1 (2.4)

440L-P2K

⊗0480YD

440L-T2KA0480YD

440L-R2K

⊗0480YD

30 (1.18)

24

480 (18.89)

1.6 (3.5)

440L-P2K

⊗0640YD

440L-T2KA0640YD

440L-R2K

⊗0640YD

30 (1.18)

32

640 (25.19)

2.0 (4.4)

440L-P2K

⊗0800YD

440L-T2KA0800YD

440L-R2K

⊗0800YD

30 (1.18)

40

800 (31.49)

2.5 (5.5)

440L-P2K

⊗0960YD

440L-T2KA0960YD

440L-R2K

⊗0960YD

30 (1.18)

48

960 (37.79)

2.9 (6.4)

440L-P2K

⊗1120YD

440L-T2KA1120YD

440L-R2K

⊗1120YD

30 (1.18)

56

1120 (44.09)

3.4 (7.5)

440L-P2K

⊗1280YD

440L-T2KA1280YD

440L-R2K

⊗1280YD

30 (1.18)

64

1280 (50.39)

3.8 (8.4)

440L-P2K

⊗1440YD

440L-T2KA1440YD

440L-R2K

⊗1440YD

30 (1.18)

72

1440 (56.69)

4.3 (9.5)

440L-P2K

⊗1600YD

440L-T2KA1600YD

440L-R2K

⊗1600YD

30 (1.18)

80

1600 (62.99)

4.7 (10.4)

440L-P2K

⊗1760YD

440L-T2KA1760YD

440L-R2K

⊗1760YD

30 (1.18)

88

1760 (69.29)

5.2 (11.5)

440L -

P

2

K

03 20 Y

D

Connector Option Micro QD

Environmental Rating IP65

0160 - Protective Height
0320
0480

0960

1440

0640

1120

1600

0800

1280

1760

K- 30 mm (1.18 in.)

Type 2

P - Pair, T - Transmitter, R - Receiver

Bulletin Number

Operating Modes
A = Guard Only
D = Restart Interlock with EDM

Advertising