Guardshield, Original instructions, Date code – Rockwell Automation 440L GuardShield Type 2 Safety Light Curtain User Manual User Manual

Page 17: Six-month inspection, Cleaning, Tran smitter receiver

Advertising
background image

R

GuardShield™ Type 2 Safety Light Curtain Installation Instructions

15

Original instructions

Proper testing of protective field using test rod

Six-Month Inspection

Check the following items every six months or whenever a machine
setting was changed.

Cleaning

If the optic front cover of the GuardShield Type 2 is dirty, the outputs of
the GuardShield Type 2 turn off. Take a clean, soft cloth and rub without
pressure. Do not apply aggressive, abrasive or scratching cleansing agents,
which might attack the surface.

Date Code

Explanation of data code

1.

Machine stops or does not obstruct any safety function.

2.

The latest machine or connection modifications have no effect on
the control system.

3.

The outputs of the GuardShield Type 2 are properly connected to
the machine.

4.

The total response time of the machine is shorter than the
calculated value.

5.

Cables and plugs of the GuardShield Type 2 are in flawless
condition.

6.

Mounting brackets, caps and cables are tightly secured.

Tran

smitter

Receiver

Location of Manufacture

Year of Manufacturer

Week of Manufacturer

X

X*

XX

M or 4K

R

02

M represented Manchester, NH replaced by 4K for Monterrey, Mexico

* J=2004

K=2005
L=2006

M=2007

N=2008
P=2009
R=2010

S=2011
T=2010

U=2013
V=2014

W=2015

Y=2016
Z=2017

Part No.

GuardShield

TM

PLD/SIL CL2,SIL2

Response Time w/o Coding

Protective Height

Range

Resolution

2 Exec

u

tive Dr. Chelm

s

ford MA. 01

8

24

Prod

u

ct of Mexico

97

8

-441-9500

Ser Rev

T2KA0320YD A A

Ser Rev

440L

Bul/Type

Part No.

T2KA0320YD

A A

AA00AA00

Ambient Temp

Power Consumption

Supply Voltage

Safety Parameters

Operating Instructions

Ref No.

Jun, 2010

PN-20857

7W max.

IP65

30mm

0.3-16m

320mm

<30ms

<20ms

-10.....+55C

24V DC +/-20%

Bul/Type

Response Time with Coding

Electro-

S

en

s

itive

Protective E

qu

ip.

19KP

Degree of Protection

Rockwell Automation

440L

IEC61496/ EN I

S

O 1

38

49

EN62061/ IEC6150

8

Type 2/Cat.2

M

a

de in

Advertising