Using basic mode, Chapter objectives, What does basic mode provide – Rockwell Automation 1203-SM1 SLC to SCANport Communication Module User Manual

Page 19: Chapter

Advertising
background image

Chapter

3

Publication 1203–5.9 –– October 1996

Using Basic Mode

Chapter 3 covers the following information:

a description of what basic mode provides

how to configure the SLC to SCANport module for basic mode

how to transfer data

Basic mode sends a 16–bit logic command and a 16–bit analog
reference from the module to each SCANport device. It receives a
16–bit logic status and a 16–bit analog feedback signal from each
connected SCANport device.

INPUT

OUTPUT

SCANport

Channel 1

Channel 2

Channel 3

CHANNEL 1

CHANNEL 2

CHANNEL 3

SLC 5/01 CPU

PC RUN
CPU Fault
FORCED I/O
BATTERY LOW

POWER

0

8

1

9

2

10

3

11

7

15

6

14

5

13

4

12

0

8

1

9

2

10

3

11

7

15

6

14

5

13

4

12

16-bit logic command
16-bit analog reference

16-bit logic status
16-bit analog feedback

16-bit logic command
16-bit analog reference (not used by SMC)

16-bit logic status
16-bit analog feedback

16-bit logic command
16-bit analog reference

16-bit logic status
16-bit analog feedback

1305

1336

SMC

To configure the SLC to SCANport module for basic mode using the
Advanced Programming Software (APS), you need to:

1. Create a file.

2. Enter a file name. For example purposes, we are using SM1_AP

as the file name.

3. Highlight the processor as shown in Figure 3.1.

Chapter Objectives

What Does Basic Mode
Provide?

Configuring the SLC to
SCANport Module for
Basic Mode

Advertising