B–22, Read product software version – Rockwell Automation 1203-SM1 SLC to SCANport Communication Module User Manual
Page 88

SCANport Messaging
B–22
Publication 1203–5.9 –– October 1996
Read Product Software Version
The Read Product Software Version message lets you request the
product software version from a SCANport device. The following is
an example of this request:
Service=Get Attribute Single
Internal A–B Vendor Specific Class
Instance
Attribute
Data Length=0 Bytes
M0:e.000
M0:e.001
M0:e.002
M0:e.003
M0:e.004
000e
0092
0001
0001
0000
Value
Read Product Software Version
Service=Get Attribute Single
Internal A–B Vendor Specific Class
Instance
Attribute
Data Length=6 Bytes
M1:e.100
M1:e.101
M1:e.102
M1:e.103
M1:e.104
000e
0092
0001
0001
0006
Value
Response
Product Software Version (00ca=202=FRN2.02)
Discard
Discard
M1:e.105
M1:e.106
M1:e.107
00ca
0000
0000
Figure B.16 shows a Read Product Software Version request. The
software version for microprocessor 1 is FRN2.02. The instance
number, set into N10:2, determines the microprocessor being
accessed by this message. Some products have multiple
microprocessors, and all products have at least one.
Figure B.16
Example of Read Product Software Version
address 0 1 2 3 4 5 6 7 8 9
N10:0 000e 0092 0001 0001 0000
address 0 1 2 3 4 5 6 7 8 9
N11:0 000e 0092 0001 0001 0006 00ca 0000 0000