Write Parameter Link from Parameter Number
The Write Parameter Link from Parameter Number message lets you
write the parameter link information for a specific parameter. The
following is an example of this request:
Service=Set Attribute Single
Internal A–B Vendor Specific Class
Instance=Parameter #5
Attribute=Link
Data Length=2 Bytes
M0:e.000
M0:e.001
M0:e.002
M0:e.003
M0:e.004
0010
0099
0005
0000
0002
Value
Write Parameter Link to Parameter Number 5
Service=Set Attribute Single
Internal A–B Vendor Specific Class
Instance=Parameter #5
Attribute=Link
Data Length=0
M1:e.100
M1:e.101
M1:e.102
M1:e.103
M1:e.104
0010
0099
0005
0000
0000
Value
Response
Link Number
M0:e.005
0007
Figure B.20 shows a Write Parameter Link from Parameter Number
request. This example is a write to the link value of parameter 5 (the
parameter number is in N10:2). The link value being written is 6.
Figure B.20
Example of Write Parameter Link from Parameter Number
address 0 1 2 3 4 5 6 7 8 9
N10:0 0010 0099 0005 0000 0002 0006
address 0 1 2 3 4 5 6 7 8 9
N11:0 0010 0099 0005 0000 0000