Rockwell Automation 1747-PT1, D1747NP002 Hand-Held Terminal User Manual
Page 135

Chapter 7
Creating and Editing a Program File
7–23
3. Press
[F2]
, MOD_RNG, then
[F2]
, BRANCH.
The following menu display appears:
I
I
I
I
I
I
F1
F2
F3
F4
F5
2.1.1.2.*
OFL
] [
( )
] [
] [
( )
<
END
>
] [
] [
]/[
EXT_UP
EXT_DWN
APP_BR
DEL_BR
INS_BR
4. Press
[F2]
, EXT_DWN. The display changes as follows:
I
I
I
I
I
I
I
F1
F2
F3
F4
F5
2.1.1.3.*
OFL
] [
( )
] [
] [
( )
] [
] [
]/[
EXT_UP
EXT_DWN
APP_BR
DEL_BR
INS_BR
I
5. Press
[ESC]
. The proper menu is displayed:
I
I
I
I
I
I
I
F1
F2
F3
F4
F5
2.1.1.3.*
] [
( )
] [
] [
( )
] [
] [
]/[
I
OFL
>
INS_INST
BRANCH
MOD_INST
ACP_RNG
6. Now insert the examine if closed instruction with address B3/3, by
pressing
[F1]
, INS_INST, then
[F1]
, BIT, then
[F1]
, —] [— .
7. In the zoom display type the address
B3/3
, then press
[ENTER]
, then,
[F5]
, ACCEPT. The display appears as follows:
I
I
I
I
I
I
I
F1
F2
F3
F4
F5
2.1.1.3.*
] [
( )
] [
] [
( )
] [
] [
]/[
I
] [
OFL
>
] [
]/[
( )
( )
L
( )
U
( )
( )
Notice that the length of the newest branch is the same as the rest.
8. Press
[ESC]
twice to return to the proper menu. Then press
[F5]
, ACP_RNG.
9. Save the changes.