Compact™ Combination Analog I/O Module 5

Publication 1769-IN057A-EN-P - July 2001

7. Attach an end cap terminator (E) to the last module in the system by using

the tongue-and-groove slots as before.

8. Lock the end cap bus terminator (F).

Mounting Expansion I/O

Minimum Spacing

Maintain spacing from
enclosure walls,
wireways, adjacent
equipment, etc. Allow 50
mm (2 in.) of space on all
sides for adequate
ventilation, as shown:

IMPORTANT

A 1769-ECR or 1769-ECL right or left end cap must be used to
terminate the end of the communication bus.

ATTENTION

!

During panel or DIN rail mounting of all devices, be sure that
all debris (metal chips, wire strands, etc.) is kept from falling
into the module. Debris that falls into the module could cause
damage on power up.

Top

Bottom

Side

Side

Host Controller