Specifications – Rockwell Automation 1771-P7 AC (120/220V) 16A Power Supply Installation Instructions User Manual

Page 15

Advertising
background image

AC (120/220V) 16A Power Supply

15

Publication 1771ĆIN056B EN-P - December 2001

Supply Voltage Range

120V ac: 97Ć132V ac 50/60Hz 2.0A

220V ac: 195Ć264V ac 50/60Hz 1.3A

Input Power (Real/Apparent)

108 Watts/176VA maximum (see charts)

External Transformer

270VA at full load

Isolation Voltage

Tested to 1200V ac for 1s

Output Voltage

5.06V dc

±

3.8%

Output Current

16A max @ 5V dc

Power Loss Time Delay Ċ

Input Power to Processor Disable

13.6ms

±

2.9ms

Maximum User-supplied Overcurrent

Protection

1

15A

Fuse

2

3A, 250V 3AG normal blow

(Bussmann AGC 3 Ċ Littelfuse 312003)

Conductor

Wire Size

Category

14AWG (2.5mm

2

) stranded copper wire rated at 75

o

C or greater

1

3

Terminal Strip Screw Torque

12 poundĆinches

Weight

1.95kg (4.3 lbs.)

Dimensions (H x W x D)

315mm x 115mm x 159mm

(12.40" x 4.53" x 6.25" )

Environmental Conditions

Operating Temperature

IEC 60068-2-1 (Test Ad, Operating Cold)

IEC 60068-2-2 (Test Bd, Operating Dry Heat)

IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

32 to 140

°

F (0 to 60

°

C)

Storage Temperature

IEC 60068-2-1 (Test Ab, Unpackaged, Nonoperating Cold)

IEC 60068-2-2 (Test Bc, Unpackaged, Nonoperating Dry Heat)

IEC 60068-2-14 (Test Na, Unpackaged, Nonoperating Thermal Shock)

-40 to 185

°

F (-40 to 85

°

C)

Relative Humidity

IEC 60068-2-30 (Test Db, Unpackaged, Nonoperating Damp Heat)

5 to 95%, noncondensing

Shock

Operating

Nonoperating

IEC 60068-2-27;1987 (Test Ea, Unpackaged Shock, ES#002)

15g

30g

Vibration

IEC 60068-2-6 (Test Fc, Operating)

2g @ 10-500Hz

Emissions

CISPR 11

Group 1, Class A

ESD Immunity

IEC 61000-4-2

4KV Contact Discharges

Radiated RF Immunity

IEC 61000-4-3

10V/m, 3V/m Broadcast bands, with 1kHz sine-wave 80% AM from

30MHz to 1000MHz

EFT/B Immunity

IEC 61000-4-4

+2kV @ 2.5kHz on power ports

Surge Transient Immunity

IEC 61000-4-5

+1kV line-line (DM) and +2kV line-earth (CM) on ac power ports

Conducted RF Immunity

IEC 61000-4-6

10V rms with 1kHz sine wave 80% AM from 150kHz to 30MHz

Enclosure Type Rating

None (open style)

Specifications