Rockwell Automation 1784-U2DHP USB-to-Data Highway Plus Cable Installation Instructions User Manual
Page 16

16 USB-to-Data Highway Plus Cable
Rockwell Automation Publication 1784-IN045C-EN-P - May 2010
Environmental Specifications - 1784-U2DHP
Attribute
Value
Temperature, operating
IEC 60068-2-1 (Test Ad,
Operating Cold),
IEC 60068-2-2 (Test Bd,
Operating Dry Heat),
IEC 60068-2-14 (Test Nb,
Operating Thermal Shock)
0…55 °C (32…131 °F)
Temperature, nonoperating
IEC 60068-2-1 (Test Ab,
Unpackaged Nonoperating
Cold),
IEC 60068-2-2 (Test Bb,
Unpackaged Nonoperating
Dry Heat),
IEC 60068-2-14 (Test Na,
Unpackaged Nonoperating
Thermal Shock)
-10…85 °C (14…185 °F)
Relative humidity
IEC 60068-2-30 (Test Db,
Unpackaged Damp Heat)
5…95% noncondensing
Shock, nonoperating
IEC 60068-2-27 (Test Ed,
Unpackaged Shock)
1000 mm (3.28 ft)
Emissions
CISPR 11
Group 1, Class A
ESD immunity
IEC 61000-4-2
8 kV air discharges
Radiated RF immunity
IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
10V/m with 1 kHz sine-wave 80% AM from 2000…
2700 MHz