Connect and configure the cable – Rockwell Automation 1784-U2DHP USB-to-Data Highway Plus Cable Installation Instructions User Manual

Page 6

Advertising
background image

6 USB-to-Data Highway Plus Cable

Rockwell Automation Publication 1784-IN045C-EN-P - May 2010

Connect and Configure the Cable

1. Insert the end of the cable having the USB connector into an unused

USB port on a computer.

The Found New Hardware wizard appears.

If you do not see the Found New Hardware wizard, proceed to

step 9

. Otherwise, continue with the next step.

2. Select No, not this time and click Next.
3. Select Install from a list or specific location and click Next.
4. Select Search for the best driver.
5. Check only the Include this location checkbox.
6. Browse to the location where you saved the 1784_u2dhp.inf file and

click OK.

7. Click Next.
8. Click Finish.

TIP

If you do not see the Found New Hardware wizard, the drivers
have already been installed. If RSLinx Classic software, version
2.53 or later, is installed on the computer, the device driver was
installed at C:\Program Files\Rockwell
Software\RSLINX\PnP_Drivers\1784-U2DHP.

TIP

If you see a Microsoft Windows error message that displays
code 10, disconnect the cable from the USB port, then reconnect
the cable to the USB port, so that the Windows operating system
recognizes the device.