1747-SDN DeviceNet Scanner Module 11

Publication 1747-IN058F-EN-P - December 2010

2.

Connect the DeviceNet drop line to the 10-pin linear plug by matching the wire
insulation colors to the colors shown on the label.

3.

Locate the DeviceNet port connector on the front of the module.

4.

Insert the 10-pin linear plug into the DeviceNet port connector.

You have installed and wired your module. To operate the module you must apply power and
then configure and program the SLC processor to communicate with it.

WARNING

If you connect or disconnect the communications cable with power applied to
this module or any device on the network, an electrical arc can occur. This could
cause an explosion in hazardous location installations.

+24V Red

Can_H White

Drain/Shield

Can_L Blue

+24V Return Black

Front of Module

10-pin linear
plug

Red

White

Shield

Blue

Black

10-pin Linear plug

DeviceNet drop line

DeviceNet port
connector