Maintenance

1788-UM002A-US-P – April 2000

Performing a Self-Test

When the MediaChecker is on, it periodically tests some
of its internal circuits. If a problem is detected, the
MediaChecker displays the following message:

aan16f.eps

You can perform a more thorough self-test on DeviceNet,
DH+/RIO, and Ethernet functions as follows:

1. With the MediaChecker off, press and hold

A

while turning the rotary switch to TEST.

2. Press

E

until “SELF-TEST?” is displayed.

3. Press

C

or

D

to select “YES”.

Important: To exit without performing a self-test, either

press

A

, or ensure that the second line is

displaying “NO” and press

E

to move to

the next setup selection.

4. Press

E

to activate the self-test program.

You will be prompted to install the Cable ID. There
are two ways to install the Cable ID, each with
different results:

To run a self-test on DeviceNet and DH+/RIO
functions, connect a DB9-to-Mini/Micro male
adapter in series with a Mini/Micro female-to-DB 9
adapter. Use this series combination to connect
between the DB9 connector on the Cable ID and
the DB9 connector on the MediaChecker.

Advertising