Specifications – Rockwell Automation 1788 NetLinx Media Checker Users Manual User Manual

Page 41

Advertising
background image

Specifications

41

1788-UM002A-US-P – April 2000

Specifications

These specifications assume the MediaChecker was
calibrated using 100 ft (30 m) (or more) of cable of the
same type and batch as the cable being measured.
Accuracy is specified for two years after calibration.

Coax Termination Measurements

Any loop resistance value between 5

and 350

is

interpreted as a terminator resistance. Resistance values
below 5

are considered shorts; resistance values

greater than 350

are displayed as

>

350

.

Input Connectors

RJ45, DB-9, and BNC

Input Protection

Will withstand connection to any of the supported
networks in a live condition with a supply voltage not
exceeding 25 V.

“ACTIVE CABLE” is displayed and an audible signal
sounds when the MediaChecker is connected to a cable
with voltage present.

ATTENTION: Never connect the
MediaChecker to any telephony inputs,
systems, or equipment, including ISDN.

Table 17. Cable Test Characteristics

Network

Cable

Wiring

Pass/Fail Pins

DeviceNet

Thick and

Thin

DeviceNet

Data pair, power

pair, shield

DeviceNet

KwikLink

DeviceNet

Data pair,

power pair

DH+/RIO

Blue Hose

or similar

DH+

Data pair, shield

ControlNet

RG6,

RG6F,

DS3/4

Coaxial

Center pin and

shield

Ethernet

UTP/FTP

EIA/TIA

4-pair

Wire pairs 1, 2;

3, 6; 4, 5; 7, 8

Also the foil

(shield) for FTP

Advertising