Table 20. DH+/RIO Cable Test Specifications

Cable Length

Distance to Short

Cable

1

Range

Accuracy

Resolution

2

Accuracy

3

Resolution

2

DH+/RIO 1770-CD
DH+/RIO 9022
DH+/RIO 9463

1 m to 350 m

(2 ft to 999 ft)

7 % + 2 m (6 ft)

See Note 2

7 % + 3 m

(7 % + 10 ft)

0.5 m (1 ft)

1. For these cable types, the length to an open is displayed, but the “OPEN” error message is not displayed.

2. 0.5 m (1 ft) for cables <100 m long (328 ft); 1 m (5 ft) for cables >100 m long; 1 ft (0.5 m) for cables to 999 ft long (305 m); 10 ft (3 m)

for cables >999 ft long.

3. For the data pair only.

Table 21. Ethernet Cable Test Specifications

Test

Range

Accuracy

Resolution

2

Cable length

7 % + 0.5 m (1 ft)

Distance to short

7 % + 3 m (7 % + 10 ft)

Distance to open

7 % + 3 m (7 % + 10 ft)

0.5 m (1 ft)

Split pairs

1

1 m to 350 m (2 ft to 999 ft)

NA

NA

1. Testing for split pairs requires 2 or more pairs with similar capacitance. Split pair section of the cable must be at least 2 meters (6 ft)

long and greater than 10 % of the total cable length.

2. 0.5 m (1 ft) for cables <100 m long (328 ft); 1 m (5 ft) for cables >100 m long; 1 ft (0.5 m) for cables to 999 ft long (305 m); 10 ft (3 m) for

cables >999 ft long.